CalamitousFelicitousness bd6abfc3e4 fix(video): resolve dropdown model selection through the registry
Both load buttons matched the dropdown value against the raw row list, so the
separators the list uses for grouping resolved to a row with no repo. The
loader returned early on that row without loading or reporting, and the ltx
tab went on to record load and offload timings for a load that never ran.

Selection now goes through models_def.find, which knows a separator names no
model, and both buttons say what happened. The ltx button had no output bound
at all, so its message went nowhere.
2026-08-18 00:46:16 +01:00
..